One range, three uses

Sizing guide

Homes, RVs and boats share this catalogue. The difference is how many watt-hours you use in a day, the largest load that can be on at once, and whether the battery must charge below freezing.

LoadWattsHoursWh
960
200
160
240

Energy for this list

1,560 Wh

If they run together

260 W

Suggestion

1 × 200Ah

  • 1 × 12.8V 200Ah · closest fit

    R12,250 for 1. About 8.9 h at 260 W together. Continuous limit 2,560 W. Charges from −20°C.

    View
  • 1 × 12.8V 300Ah

    R15,850 for 1. About 13.3 h at 260 W together. Continuous limit 2,560 W. Do not charge below about 0°C.

    View
  • 1 × 12.8V 300Ah Self-Cooling

    R22,450 for 1. About 13.3 h at 260 W together. Continuous limit 3,840 W. Charges from −20°C.

    View

Uses 90% of nameplate watt-hours and assumes the listed loads can be on at once. Estimates only — inverter losses (about 10–15%), start-up surges and temperature are not included. Real fridge and trolling-motor draw cycles. Resting voltage, not inverter load, is how the manuals say to read state of charge. Ask Danie for this setup.

Home backup

Add the appliances you actually keep on. A 120W fridge for 8 hours is already about 1kWh before lights and Wi-Fi. Match the inverter to the battery’s max load: 1,920W on the 100Ah, 2,560W on the 200Ah and the standard 300Ah, 3,840W on the rest.

RV and camper

A weekend with a compressor fridge, lights and a laptop often sits on a 300Ah. Longer off-grid stays and inverter cooking move you to 460Ah, 560Ah or 600Ah. If you charge on cold mornings, pick a model rated to charge from −20°C: the 200Ah, the 300Ah cooling fan, or the 560Ah.

Boat

House loads are similar to an RV. A trolling motor is the number that blows the watt limit — 300W for a few hours is fine on the larger packs; a heavy motor may need two identical batteries in parallel so the current adds up.

Which cold behaviour

Charges from −20°CLow-temp cut-off
Models200Ah, 300Ah cooling fan, 560Ah100Ah, 300Ah 1500 CCA, 460Ah, 600Ah
ChargingCharge range −20°C to 50°C. Discharge still cuts off near −20°C.Charging stops near 0°C ± 4°C. Do not force a charge in a frost.
DischargingBoth families cut discharge off near −20°C.

A resting-voltage sketch

Approximate resting-voltage guide (not from the Vatrer manuals). Measure at the posts 15 minutes after everything is disconnected, with no current flowing.

  • 100%13.5V
  • 90%13.3V
  • 70%13.2V
  • 30%13.0V
  • 10%12.8V
Full state-of-charge table and MPPT settings